IPR International Reading, PA United States

IPR International

Reading, PA
United States

Location IPR Reading Business Continuity Center, Reading, PA United States
About
Company

IPR International, LLC was founded on a simple concept: that technology will change at such a rapid pace that most mid-size organizations will not be able to keep up with it, and thus that we would dedicate ourselves to providing the best-of-breed, state-of the-art data protection technologies available so that our clients can focus on their core business operations with the secure knowledge that their electronic data is safe and accessible to them at all times.

IPR International Logo

Facility
Facility
  • Tier 3+ data center - 37 feet underground built on a 4 foot thick floating slab. Base is clay.
  • 60,000 sq ft of underground raised floor
  • 50,000 sq ft of above ground raised floor
  • Green Facility since 1985
    • Heat re-cycling unit to capture heat from data centers to be reused internally to heat the non-raised floor area
    • Capability to make slush to cool the water for the chillers to drives power costs down
  • 24 inch raised floor built to load capacity of 150 lb/sf, 21 feet slab to slab clearance
  • Workstations for 1000
  • Onsite cafeteria, showers, lockers
  • Private airport with heliport, major highways and public transportation to front door for easy access in time of disaster
Physical geography

Flood plains and zones based on elevation of lowest floor:

  • 89 feet above 100 year flood plain
  • 85 feet above 500 year flood plain
  • 4000 feet from 500 year flood zone
HVAC
  • Four 300 ton Trane units
  • Two heat recovery systems
  • N+1redundant
  • Water leak detection system
  • Two 15,000 gallon water tanks to act on stand-by
  • Commercial water, along with backup water supply for cooling towers, plus underground pumps with wells
  • Facility is capable of making its own slush to chill the water should power rates increase
  • Backup water supply for cooling towers, plus well
Power
Redundant Power
  • N+1 redundancy of uninterruptible power
  • Three separate 13.2 kV power feeds supplied by (3) geographically diverse substation feeds
  • 69 kV substation on-site expansion in 2009
  • Three geographically diverse substations
  • Substations on power ring
  • Automatic/Parallel switch gear
  • Dual power availability to each rack unit from independent power distribution units (PDUs) removes single PDU loss as a point of failure
Emergency Power
  • UPS
    • Redundant
    • Three 500 KVA parallel units
    • Full capacity: 20 minutes
    • One hour @ 500 KVA
  • Data center generators
    • Five 2 megawatt generators
    • One 1.25 megawatt generators
    • Two 15,000 gallon fuel tanks
      • One underground
      • One above ground
  • Two life safety generators
    • 120 kilowatts each
    • 3,000 gallons each
Security
  • 24 x 7 manned security command center
  • Key card access
  • 45 closed circuit cameras
  • Fire suppression system
Network
  • Multiple carriers and last mile fiber providers for connectivity
  • Redundant core routing for Internet
  • Carrier-class routing equipment is used in IPR data centers
  • Seven state redundant private fiber ring with access to over 60 cities