About Company |
Equinix, Inc. (Nasdaq: EQIX) operates International Business Exchange™ (IBX®) data centers in 35 markets across 11 countries in North America, Europe, and Asia-Pacific. Global enterprises, content and financial companies, and network services providers rely upon Equinix’s insight and expertise to protect and connect their most valued information assets.

|
| Facility |
Square Feet:44,382 Floor Load:Rating = Live Load Ex. 200#/sf Roof Rights:Roof rights available Product Availability • Cage Space Available • Cabinets Available • UPS Power Available • DC Power Available • Standard Cross Connects --- DS0, DS1, DS3, Ethernet, Fiber • PAIX Ports – 100 Mbps, 333 Mbps (Fractional GigE), 500 Mbps (Half GigE), 1000 Mbps or Gigabit Ethernet (GigE), NxGigE 2-4-6-8, 10 GigE 6-8, 10 GigE • SingleCNXT-i (Internet Access) • TechSmart® (Remote Hands): 24/7/365 Technical Support • Roof Space • Network Timing: GPS (primary) and CDMA (redundant) time source Certification:SAS 70 Type I Compliant Fire Supression • Pre-Action double interlock fire suppression system • Multi zoned smoke and heat fire alarm detection system HVAC • 1100 Tons of Heat Rejection Capacity • Interior and exterior systems are each deployed at N + 1 • A/C units maintain a climate of 72 degrees (+/- 5) and 30-60% humidity (SLA Statement) Alarm Monitoring • All essential equipment is tied into Falcon Alarm System (UPS, DC plant, PMMs, BDCBBs, ATS’s, Generators, Diesel tanks, TVSS, Fire System) • Operations Alarm Management (OAM) Group monitors facility falcon units 24/7/365 • Alarming is a dry contact system set to normally closed Seismic • Seismic Zone -- with importance factor in excess of 1.25 • Concrete tilt-up with steel column construction • Steel seismic bracing • All cabinet and racks are installed with seismic bracing • All mechanical, electrical, HVAC systems are seismically braced including ductwork, piping, conduits and CRAC units |
| Power |
Power Density:200 Watts Per Sq. Ft. of equipment floor UPS System • Four parallel UPS systems configured N+1 • Primary UPS systems provide 1300Kva • UPS System deployed to carry full design load 12 – 15 minutes DC Plant • Fully redundant DC plant system • System is deployed as A & B plants design classification as N+1 • 6400 amps of matching DC sub-distribution infrastructure • DC Plant systems are deployed to carry full load for 4 hours via dedicated battery banks per DC plant • -48 Volt DC Battery Plant • 6400 amp expandable to 10,000 amp • 2-hour battery reserve non-redundant, 4 hours redundant Standby Generator • Three 1250 KVA Generators (critical load) Five 750 KVA generators (mechanical load) • Two 20,000 gallon underground fuel tanks • Generator systems both auto start and auto transfer(building owned) |
| Network |
AboveNet Allied Telecom Cogent Cox Communications Fiberlight Fibergate Internap Ironpath Level3 (Wiltel, Progress Telecom, Looking Glass) MegaPath Neon (RCN) Qwest (On Fiber & Telcove) PPL (Cambrian) Reliance Globalcom SingleCNXT Verizon (MCI) Video Presence XO Communications Yipes Zayo Bandwidth |