About Company |
Equinix, Inc. (Nasdaq: EQIX) operates International Business Exchange™ (IBX®) data centers in 35 markets across 11 countries in North America, Europe, and Asia-Pacific. Global enterprises, content and financial companies, and network services providers rely upon Equinix’s insight and expertise to protect and connect their most valued information assets.

|
| Facility |
Square Feet:163,537 Floor Load:Live Load Ex. 175#/sf first and second floors, 100 #/sf third floor Roof Rights:Roof rights available Product Availability • Cage Space Available • Cabinets Available • UPS Power Available • DC Power Available • Standard Cross Connects --- DS0, DS1, DS3, Ethernet, Fiber • Metro Cross Connects --- (access to meet-me-rooms in NYC 111 8th and 60 Hudson) --- Ethernet, GigE • PAIX Ports --- 100 Mbps, 333 Mbps (Fractional GigE), 500 Mbps (Half GigE), 1000 Mbps or Gigabit • Ethernet (GigE), NxGigE 2-4-6-8, 10 GigE 6-8, 10 GigE • SingleCNXT-i (Internet Acess) --- Access to bandwidth providers in NYC 111 8th and 60 Hudson • TechSmart® (Remote Hands): 24/7/365 Technical Support • Network Timing: GPS (primary) and CDMA (redundant) time source Fire Supression • Pre-Action double interlock fire suppression system • Dual zoned smoke and heat fire alarm detection system HVAC • 14259 KW of Heat Rejection Capacity • Interior and exterior systems are each deployed at N + 1 • A/C units maintain a climate of 72 degrees (+/- 5) and 30-60% humidity (SLA Statement) Alarm Monitoring • All essential equipment is tied into Falcon Alarm System (UPS, DC plant, PMMs, BDCBBs, ATS’s, Generators, Diesel tanks, TVSS, Fire System) • Operations Alarm Management (OAM) Group monitors facility falcon units 24/7/365 • Alarming is a dry contact system set to normally closed |
| Power |
Power Density • 6.0KW Max (utilization) UPS System • 7125 KW UPS System • System is deployed as N + 1 • UPS Battery backup systems are deployed to carry full design load for 15 minutes • UPS distribution systems support 7125 KW primary with 50% additional for redundant circuits DC Plant • Six redundant DC plant systems • Each DC System is deployed as A & B plants design classification as 2N • Primary DC power systems provide 691 kW • 1037 kW of matching DC sub-distribution infrastructure • DC Plant systems are deployed to carry full load for 4 hours via dedicated battery banks per DC plant • -48 Volt DC Battery Plant • 2400 amp expandable to 10,000 amp • 2-hour battery reserve non-redundant, 4 hours redundant • ‘‘True’’ A/B Power feeds Standby Generator • 14000 KW generator systems deployed as N • 24 hours of continuous generator run time at full design load • Generator systems both auto start and auto transfer |